Water air curtain, dedicated to operate with low temperature heating medium, horizontal and vertical mounting, housing made of powder coated steel, dynamically starting EC fans, automatic operating modes adapting to the weather conditions (OPTIsmart), protection class IP21, can be connected to BMS, max. mounting height 3.6 m , heating power at 60/40°C water and 18°C air temperature: from 8.1 kW at min. airflow to 12.9 kW at max. airflow, temperature increase ΔT 26-21°C, 3 row heat exchanger, air flow 900-1800 m³/h, max. electrical power consumption 270 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 38.5 kg, 2 year WARRANTY
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
ELiS AX36 - dedicated to operate with low temperature heating medium, horizontal and vertical mounting, housing made of powder coated steel, dynamically starting EC fans, automatic operating modes adapting to the weather conditions (OPTIsmart), protection class IP21, can be connected to BMS, max. mounting height 3.6 m
ELiS AX36-W3R-100 Heating power at 60/40°C water and 18°C air temperature: from 8.1 kW at min. airflow to 12.9 kW at max. airflow, temperature increase ΔT 26-21°C, 3 row heat exchanger, air flow 900-1800 m³/h, max. electrical power consumption 270 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 38.5 kg, 2 year WARRANTY
ELiS AX36-W3R-100
Heating power at 60/40°C water and 18°C air temperature: from 8.1 kW at min. airflow to 12.9 kW at max. airflow, temperature increase ΔT 26-21°C, 3 row heat exchanger, air flow 900-1800 m³/h, max. electrical power consumption 270 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 38.5 kg, 2 year WARRANTY
ELiS AX36-W3R-150 Heating power at 60/40°C water and 18°C air temperature: from 11.8 kW at min. airflow to 20.5 kW at max. airflow, temperature increase ΔT 29-22°C, 3 row heat exchanger, air flow 1200-2700 m³/h, max. electrical power consumption 400 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 53.3 kg, 2 year WARRANTY
ELiS AX36-W3R-150
Heating power at 60/40°C water and 18°C air temperature: from 11.8 kW at min. airflow to 20.5 kW at max. airflow, temperature increase ΔT 29-22°C, 3 row heat exchanger, air flow 1200-2700 m³/h, max. electrical power consumption 400 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 53.3 kg, 2 year WARRANTY
ELiS AX36-W3R-200 Heating power at 60/40°C water and 18°C air temperature: from 17.1 kW at min. airflow to 29.0 kW at max. airflow, temperature increase ΔT 25-20°C, 3 row heat exchanger, air flow 2000-4300 m³/h, max. electrical power consumption 670 W, acoustic pressure level 45-63 dB(A), covered door gap 2 m, weight 71.7 kg, 2 year WARRANTY
ELiS AX36-W3R-200
Heating power at 60/40°C water and 18°C air temperature: from 17.1 kW at min. airflow to 29.0 kW at max. airflow, temperature increase ΔT 25-20°C, 3 row heat exchanger, air flow 2000-4300 m³/h, max. electrical power consumption 670 W, acoustic pressure level 45-63 dB(A), covered door gap 2 m, weight 71.7 kg, 2 year WARRANTY
ELiS AX36-W3R-250 Heating power at 60/40°C water and 18°C air temperature: from 21.4 kW at min. airflow to 38.0 kW at max. airflow, temperature increase ΔT 27-21°C, 3 row heat exchanger, air flow 2300-5300 m³/h, max. electrical power consumption 810 W, acoustic pressure level 46-64 dB(A), covered door gap 2.5 m, weight 86.8 kg, 2 year WARRANTY
ELiS AX36-W3R-250
Heating power at 60/40°C water and 18°C air temperature: from 21.4 kW at min. airflow to 38.0 kW at max. airflow, temperature increase ΔT 27-21°C, 3 row heat exchanger, air flow 2300-5300 m³/h, max. electrical power consumption 810 W, acoustic pressure level 46-64 dB(A), covered door gap 2.5 m, weight 86.8 kg, 2 year WARRANTY
ELiS AX36-W4R-100 Heating power at 60/40°C water and 18°C air temperature: from 8.7 kW at min. airflow to 15.2 kW at max. airflow, temperature increase ΔT 32-26°C, 4 row heat exchanger, air flow 800-1700 m³/h, max. electrical power consumption 270 W, acoustic pressure level 41-59 dB(A), covered door gap 1 m, weight 40.0 kg, 2 year WARRANTY
ELiS AX36-W4R-100
Heating power at 60/40°C water and 18°C air temperature: from 8.7 kW at min. airflow to 15.2 kW at max. airflow, temperature increase ΔT 32-26°C, 4 row heat exchanger, air flow 800-1700 m³/h, max. electrical power consumption 270 W, acoustic pressure level 41-59 dB(A), covered door gap 1 m, weight 40.0 kg, 2 year WARRANTY
ELiS AX36-W4R-150 Heating power at 60/40°C water and 18°C air temperature: from 12.7 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 34-27°C, 4 row heat exchanger, air flow 1100-2600 m³/h, max. electrical power consumption 400 W, acoustic pressure level 42-60 dB(A), covered door gap 1.5 m, weight 55.6 kg, 2 year WARRANTY
ELiS AX36-W4R-150
Heating power at 60/40°C water and 18°C air temperature: from 12.7 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 34-27°C, 4 row heat exchanger, air flow 1100-2600 m³/h, max. electrical power consumption 400 W, acoustic pressure level 42-60 dB(A), covered door gap 1.5 m, weight 55.6 kg, 2 year WARRANTY
ELiS AX36-W4R-200 Heating power at 60/40°C water and 18°C air temperature: from 20.6 kW at min. airflow to 36.7 kW at max. airflow, temperature increase ΔT 31-26°C, 4 row heat exchanger, air flow 1900-4200 m³/h, max. electrical power consumption 670 W, acoustic pressure level 44-62 dB(A), covered door gap 2 m, weight 74.8 kg, 2 year WARRANTY
ELiS AX36-W4R-200
Heating power at 60/40°C water and 18°C air temperature: from 20.6 kW at min. airflow to 36.7 kW at max. airflow, temperature increase ΔT 31-26°C, 4 row heat exchanger, air flow 1900-4200 m³/h, max. electrical power consumption 670 W, acoustic pressure level 44-62 dB(A), covered door gap 2 m, weight 74.8 kg, 2 year WARRANTY
ELiS AX36-W4R-250 Heating power at 60/40°C water and 18°C air temperature: from 24.7 kW at min. airflow to 46.6 kW at max. airflow, temperature increase ΔT 33-26°C, 4 row heat exchanger, air flow 2200-5200 m³/h, max. electrical power consumption 810 W, acoustic pressure level 45-63 dB(A), covered door gap 2.5 m, weight 90.3 kg, 2 year WARRANTY
ELiS AX36-W4R-250
Heating power at 60/40°C water and 18°C air temperature: from 24.7 kW at min. airflow to 46.6 kW at max. airflow, temperature increase ΔT 33-26°C, 4 row heat exchanger, air flow 2200-5200 m³/h, max. electrical power consumption 810 W, acoustic pressure level 45-63 dB(A), covered door gap 2.5 m, weight 90.3 kg, 2 year WARRANTY
ELiS AX45 - dedicated to operate with low temperature heating medium, horizontal and vertical mounting, housing made of powder coated steel, dynamically starting EC fans, automatic operating modes adapting to the weather conditions (OPTIsmart), protection class IP21, can be connected to BMS, max. mounting height 4.5 m
ELiS AX45-W3R-100 Heating power at 60/40°C water and 18°C air temperature: from 9.3 kW at min. airflow to 15.7 kW at max. airflow, temperature increase ΔT 25-18°C, 3 row heat exchanger, air flow 1100-2500 m³/h, max. electrical power consumption 490 W, acoustic pressure level 43-61 dB(A), covered door gap 1 m, weight 40.8 kg, 2 year WARRANTY
ELiS AX45-W3R-100
Heating power at 60/40°C water and 18°C air temperature: from 9.3 kW at min. airflow to 15.7 kW at max. airflow, temperature increase ΔT 25-18°C, 3 row heat exchanger, air flow 1100-2500 m³/h, max. electrical power consumption 490 W, acoustic pressure level 43-61 dB(A), covered door gap 1 m, weight 40.8 kg, 2 year WARRANTY
ELiS AX45-W3R-150 Heating power at 60/40°C water and 18°C air temperature: from 13.9 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 1500-3500 m³/h, max. electrical power consumption 650 W, acoustic pressure level 44-62 dB(A), covered door gap 1.5 m, weight 55.5 kg, 2 year WARRANTY
ELiS AX45-W3R-150
Heating power at 60/40°C water and 18°C air temperature: from 13.9 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 1500-3500 m³/h, max. electrical power consumption 650 W, acoustic pressure level 44-62 dB(A), covered door gap 1.5 m, weight 55.5 kg, 2 year WARRANTY
ELiS AX45-W3R-200 Heating power at 60/40°C water and 18°C air temperature: from 18.4 kW at min. airflow to 31.8 kW at max. airflow, temperature increase ΔT 24-19°C, 3 row heat exchanger, air flow 2200-5000 m³/h, max. electrical power consumption 990 W, acoustic pressure level 45-64 dB(A), covered door gap 2 m, weight 73.7 kg, 2 year WARRANTY
ELiS AX45-W3R-200
Heating power at 60/40°C water and 18°C air temperature: from 18.4 kW at min. airflow to 31.8 kW at max. airflow, temperature increase ΔT 24-19°C, 3 row heat exchanger, air flow 2200-5000 m³/h, max. electrical power consumption 990 W, acoustic pressure level 45-64 dB(A), covered door gap 2 m, weight 73.7 kg, 2 year WARRANTY
ELiS AX45-W3R-250 Heating power at 60/40°C water and 18°C air temperature: from 22.1 kW at min. airflow to 41.4 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 2400-6100 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 46-65 dB(A), covered door gap 2.5 m, weight 88.8 kg, 2 year WARRANTY
ELiS AX45-W3R-250
Heating power at 60/40°C water and 18°C air temperature: from 22.1 kW at min. airflow to 41.4 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 2400-6100 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 46-65 dB(A), covered door gap 2.5 m, weight 88.8 kg, 2 year WARRANTY
ELiS AX45-W4R-100 Heating power at 60/40°C water and 18°C air temperature: from 10.3 kW at min. airflow to 19.1 kW at max. airflow, temperature increase ΔT 30-23°C, 4 row heat exchanger, air flow 1000-2400 m³/h, max. electrical power consumption 490 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 42.3 kg, 2 year WARRANTY
ELiS AX45-W4R-100
Heating power at 60/40°C water and 18°C air temperature: from 10.3 kW at min. airflow to 19.1 kW at max. airflow, temperature increase ΔT 30-23°C, 4 row heat exchanger, air flow 1000-2400 m³/h, max. electrical power consumption 490 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 42.3 kg, 2 year WARRANTY
ELiS AX45-W4R-150 Heating power at 60/40°C water and 18°C air temperature: from 15.3 kW at min. airflow to 28.9 kW at max. airflow, temperature increase ΔT 32-25°C, 4 row heat exchanger, air flow 1400-3400 m³/h, max. electrical power consumption 650 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 57.8 kg, 2 year WARRANTY
ELiS AX45-W4R-150
Heating power at 60/40°C water and 18°C air temperature: from 15.3 kW at min. airflow to 28.9 kW at max. airflow, temperature increase ΔT 32-25°C, 4 row heat exchanger, air flow 1400-3400 m³/h, max. electrical power consumption 650 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 57.8 kg, 2 year WARRANTY
ELiS AX45-W4R-200 Heating power at 60/40°C water and 18°C air temperature: from 22.2 kW at min. airflow to 40.6 kW at max. airflow, temperature increase ΔT 31-24°C, 4 row heat exchanger, air flow 2100-4900 m³/h, max. electrical power consumption 990 W, acoustic pressure level 44-63 dB(A), covered door gap 2 m, weight 76.8 kg, 2 year WARRANTY
ELiS AX45-W4R-200
Heating power at 60/40°C water and 18°C air temperature: from 22.2 kW at min. airflow to 40.6 kW at max. airflow, temperature increase ΔT 31-24°C, 4 row heat exchanger, air flow 2100-4900 m³/h, max. electrical power consumption 990 W, acoustic pressure level 44-63 dB(A), covered door gap 2 m, weight 76.8 kg, 2 year WARRANTY
ELiS AX45-W4R-250 Heating power at 60/40°C water and 18°C air temperature: from 25.6 kW at min. airflow to 51.3 kW at max. airflow, temperature increase ΔT 33-25°C, 4 row heat exchanger, air flow 2300-6000 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 45-64 dB(A), covered door gap 2.5 m, weight 92.3 kg, 2 year WARRANTY
ELiS AX45-W4R-250
Heating power at 60/40°C water and 18°C air temperature: from 25.6 kW at min. airflow to 51.3 kW at max. airflow, temperature increase ΔT 33-25°C, 4 row heat exchanger, air flow 2300-6000 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 45-64 dB(A), covered door gap 2.5 m, weight 92.3 kg, 2 year WARRANTY
Model: ELiS AX36-W3R-100
General data
Heating capacity at 60/40°C water and 18°C air temperature, fan at max speed
kW
12,9
Heating capacity at 60/40°C water and 18°C air temperature, fan at min speed
kW
8,1
Air temperature rise ΔT at 60/40°C water and 18°C air temperature, fan at max speed
°C
21
Air temperature rise ΔT at 60/40°C water and 18°C air temperature, fan at min speed
°C
26
Air flow range
m
3,6
Max. air flow
m³/h
1800
Fan data
Air flow
m³/h
900 - 1800
Acoustic pressure level at a distance of 2 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
42 - 60
Fan type
EC
Installation data
Power supply
V/Hz
230/50
Max. power consumption
W
270
Max. current consumption
A
2,3
IP protection class
21
Installation
Horizontal & vertical
Max. operating temperature
°C
30
Max. heating water temperature
°C
60
Max. operating pressure
MPa
1,6
Hydraulic connection
Ø "
3/4
Other data
Number of rows of the heat exchanger
3
Dimensions
Length
mm
1123
Depth
mm
670
Height
mm
293
Weight
kg
38,5

Dimensions

Model: ELiS AX36-W3R-100

Heating capacity tables

ELiS AX36-W3R-100 airflow = 1800 m³/h
Tp1
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
 
0
10
20
Tw1/Tw2 = 60/40°C
21,0
915
8,7
34,0
16,5
721
5,6
37,0
11,9
520
3,1
39,5
 
0
10
20
Tw1/Tw2 = 50/40°C
19,2
1675
26,9
31,5
14,9
1295
16,8
34,0
10,4
909
8,8
37,0
 
0
10
20
Tw1/Tw2 = 45/35°C
17,0
1474
21,7
27,5
12,6
1095
12,6
30,5
8,1
706
5,6
33,0
 
0
10
20
Tw1/Tw2 = 40/30°C
14,7
1273
16,8
24,0
10,3
893
8,8
26,5
5,7
497
3,0
29,5
  • PT - heating capacity
  • Tp1 - air temperature at the unit inlet
  • Tp2 - air temperature at the unit outlet
  • Tw1 - heating medium temperature at the heat exchanger inlet
  • Tw2 - heating medium temperature at the heat exchanger outlet
  • Qw - heating medium flow rate in heat exchanger
  • Δpw - heating medium pressure drop in heat exchanger

If you want to calculate heating capacity at different parameters you can do this at manufacturer website.

ELiS AX air curtains
Manuals 7.6 MB
Declarations of conformity 236 KB
Brochures 1016 KB
Presentation 46.7 MB
Catalogue 1.2 MB
BIM objects 6.5 MB
ELiS AX air curtains presentation