Gas absorption heat pump, takes heat from Air and gives it to Water for heating or domestic hot water production, connected with additional condensing boiler, maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
GITIE-AHAY - takes heat from Air and gives it to Water for heating or domestic hot water production, connected with additional condensing boiler
GITIE AHAY35/2 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -25°C, 2-pipe hydraulic connection
GITIE AHAY35/2 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -25°C, 2-pipe hydraulic connection
GITIE AHAY35/4 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY35/4 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY35/2 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 2-pipe hydraulic connection
GITIE AHAY35/2 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 2-pipe hydraulic connection
GITIE AHAY35/4 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY35/4 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY50/2 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/2 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/4 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection
GITIE AHAY50/4 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection
GITIE AHAY50/2 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/2 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/4 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection
GITIE AHAY50/4 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection

Gas powered absorption heat pump with additional condensing boiler GITIE-AHAY is designed for high efficiency heating and domestic hot water production up to 80°C with low electric energy consumption.

Gitié is the perfect blend of two winning technologies: the airsource absorption heat pump and the condensing boiler, both powered by natural gas. Gitié can provide up to 3 services:

  • high efficiency heating;
  • hot water production up to 80°C;
  • cooling with low electric energy consumption.

Advantages

  • Gitié, integrated, preassembled and custommade in the manufacturing plant, is a fully plug-‘n-play system. This can facilitate correct installation, avoiding the complexity of the integration on field of solar thermal systems.
  • Gitié is the all-in-one solution replacing a boiler + solar thermal system using airsource renewable energy available 24-hours-a-day. For each kW of natural gas equivalent used, Gitié adds 0.5 kW of renewable energy.
  • Gitié capital cost is convenient and it provides up to 40% of running cost savings if compared with similar solutions.
  • It is eligible for national and local incentive programs all over Europe.
  • Use of natural refrigerants not subject to normal constraints and phase-out (F-Gas Regulation exempt).

Applications

  • Ideal for residential, industrial, commercial and hospitality facilities.
  • Suitable for both new and existing buildings as it’s for fitting in heating systems with low temperature (radiant heating or fan coils) or high temperature (radiators) distribution systems.
  • Outdoor installation.

Versions

  • Available in standard or low noise version, 2 and 4 pipes, with or without modulating circulators.

GITIE-AHAY is an integrated outdoor package comprising of:

  • air-source gas absorption heat pump GAHP-A;
  • condensing boiler AY.

Standard configuration

  • 4-pipe service plate for water and gas connections.
  • Electrical box for:
    • external control systems connections (like room thermostats, timers etc.);
    • Direct Digital Control (optional) connection;
    • water pumps connection.
  • Steel rail.

Low noise version

With low-noise fan unit and a special sound-proof insulated casing. Ideal for installations where noise reduction is required.

Hydraulic kit

  • 2 pipes (KIT /2 C0):
    • Single water loop;
    • Two motorized and factory wired check valves to optimize the efficiency of the system
  • 2 pipes with circulators (KIT /2 C1):
    • Single water loop with circulators;
    • Two high efficiency and factory wired circulators (ErP Directive) to optimize the water flow and efficiency of the system.
  • 4 pipes with circulators (KIT /4 C1):
    • Two independent water loops with circulators;
    • Two high efficiency and factory wired circulators (ErP Directive) to optimize the water flow of the system.

Accessories

  • Direct Digital Control for a smart system management.
  • RoburBox100 for a smart control interface of domestic hot production management (Direct Digital Control required).
  • Outdoor temperature probe.
  • CAN BUS cable.
  • High efficiency circulators (ErP Directive) with increased pressure head.
  • Vibration dampers.
  • Gas/LPG conversion kit.
GITIE-AHAY gas absorption heat pump Air/Water with additional condensing boiler
Manuals 13 MB
Declarations of conformity 2.9 MB
Catalogue 3.5 MB
DDC control panel
Manuals 1.8 MB
Brochures 795 KB
MODBUS protocol for connection to BMS 690 KB
RB100 (Robur Box 100) control interface
Manuals 3.1 MB