Gas absorption heat pump, geothermal, takes heat from Ground and gives it to Water for heating or domestic hot water production, maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.6 kW (B0/W35), G.U.E. gas utilization efficiency 165% (B0/W35), A++ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption 0.41 kW, sound pressure level (at 5 m distance) 44.1 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 300 kg, outside working temperature -15°C/+45°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
GAHP-GS - geothermal, takes heat from Ground and gives it to Water for heating or domestic hot water production
GAHP-GS Maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.6 kW (B0/W35), G.U.E. gas utilization efficiency 165% (B0/W35), A++ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption 0.41 kW, sound pressure level (at 5 m distance) 44.1 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 300 kg, outside working temperature -15°C/+45°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
GAHP-GS
Maximum outlet water temperature for heating/DHW 65/70°C, heating capacity 41.6 kW (B0/W35), G.U.E. gas utilization efficiency 165% (B0/W35), A++ energy class ErP on 55°C operation, gas (G20) consumption 2.67 m³/h, electrical power consumption 0.41 kW, sound pressure level (at 5 m distance) 44.1 dB(A), water connection 1¼", electrical degree of protection IP X5D, weight 300 kg, outside working temperature -15°C/+45°C, can be ordered with special winter kit for operation on lower temperature down to -30°C
Model: GAHP-GS
Heating operation mode data
Energy class (55°C operation)
ErP
A++
G.U.E. gas utilization efficiency at 35°C water and 0°C ground temperature
%
165
Heating capacity at 35°C water and 0°C ground temperature
kW
41,6
Heating capacity recovered from renewable source at 35°C water and 0°C ground temperature
kW
16,4
G.U.E. gas utilization efficiency at 50°C water and 0°C ground temperature
%
149
Heating capacity at 50°C water and 0°C ground temperature
kW
37,6
Heating capacity recovered from renewable source at 50°C water and 0°C ground temperature
kW
12,1
Nominal water flow rate (ΔT = 10°C)
m³/h
3,17
Nominal water pressure loss (outlet water at 50°C)
kPa
49
Maximum outlet water temperature (heating / DHW)
°C
65 / 70
Maximum inlet water temperature (heating / DHW)
°C
55 / 60
Operating temperature range
°C
-15 / +45
Operating temperature range with winter kit
°C
-30 / +45
Burner characteristics
Thermal input (actual)
kW
25,2
Natural gas (G20) consumption at 15 °C - 1013 mbar
m³/h
2,67
LPG G30 / G31 consumption at 15 °C - 1013 mbar
kg/h
1,99 / 1,96
Installation data
Power supply
V/Hz
230/50
Nominal electrical power consumption
kW
0,41
Sound pressure at 5 meters distance from unit front side in free field
dB(A)
44,1
IP protection class
X5D
Hydraulic connection
Ø "
F 1 1/4
Gas connection
Ø "
F 3/4
Exhaust air flue diameter
mm Ø
80
Dimensions
Width
mm
848
Depth
mm
690
Height
mm
1278
Weight
kg
300

Dimensions

Model: GAHP-GS

Gas powered absorption heat pump GAHP-GS is designed for high efficiency heating and domestic hot water production in geothermal applications.

Advantages

  • Up to 39.4% utilisation of ground-source renewable energy. Designed to exceed peak efficiency (G.U.E. - Gas Utilization Efficiency) of 165%
  • Reduction in investment costs for geothermal loops can be higher than 50% in comparison to electric heat pumps.
  • It is a super-efficient solution for domestic hot water production.
  • It provides up to 40% of running cost savings if compared with the best condensing boilers.
  • It represents the most profitable investment to increase the value of the building and its energy performance rating.
  • It reduces electricity requirements compared to traditional electrical systems, thanks to the prevalent use of natural gas.
  • It is eligible for national and local incentive programs all over Europe.
  • With a GAHP-GS, every year 4.6 Tons of CO2 emissions are saved, which are equivalent to those absorbed by 656 trees or those produced by 2 green cars; every year 2.2 Tons of Oil Equivalent are saved. Moreover, Robur GAHP-GS uses natural refrigerants not subject to normal constraints and phase-out (F-Gas Regulation exempt).

Applications

  • Ideal for heating and DHW in buildings with high natural gas/LPG consumption.
  • Ability to supply cooling as free-cooling mode (unit off) or in geothermal applications with active cooling (unit on).
  • For indoor and outdoor installation.

Versions

  • Available also in:
    • pre-assembled units for higher capacity.
GAHP-GS geothermal gas absorption heat pump Ground/Water
Manuals 8.4 MB
Declarations of conformity 3.9 MB
Catalogue 3.5 MB
BIM objects 1.3 MB
Comfort Control Interface installation and use manual 798 KB
Multiple preassembled groups (Link) installation, user and maintenance manual 15 MB
DDC control panel
Manuals 1.8 MB
Brochures 795 KB
MODBUS protocol for connection to BMS 690 KB
RB100 (Robur Box 100) control interface
Manuals 3.1 MB
RB200 (Robur Box 200) control interface