Gas heater, for external installation on wall or roof, fully insulated casing, condensing version, with centrifugal fan for ducts system, pre-mix burner, 11-32 kW modulating heat output, air flow 2800 m³/h at 120 Pa, fan power 0.58 kW, max. gas (G20) consumption 3.39 m³/h, weight 86 kg, 2 year WARRANTY
Interested in this product? Contact us: Get Offer
Click on the Model for technical data, dimensions, accessories
EOLO NBC AC MIX - for external installation on wall or roof, fully insulated casing, non-condensing version, with centrifugal fan for ducts system, pre-mix burner
EOLO NBC 25 AC MIX 15-22 kW modulating heat output, air flow 2200 m³/h at 120 Pa, fan power 0.54 kW, max. gas (G20) consumption 2.33 m³/h, weight 75 kg, 2 year WARRANTY
EOLO NBC 25 AC MIX
15-22 kW modulating heat output, air flow 2200 m³/h at 120 Pa, fan power 0.54 kW, max. gas (G20) consumption 2.33 m³/h, weight 75 kg, 2 year WARRANTY
EOLO NBC 35 AC MIX 20-32 kW modulating heat output, air flow 2800 m³/h at 120 Pa, fan power 0.58 kW, max. gas (G20) consumption 3.39 m³/h, weight 86 kg, 2 year WARRANTY
EOLO NBC 35 AC MIX
20-32 kW modulating heat output, air flow 2800 m³/h at 120 Pa, fan power 0.58 kW, max. gas (G20) consumption 3.39 m³/h, weight 86 kg, 2 year WARRANTY
EOLO NBC 45 AC MIX 28-43 kW modulating heat output, air flow 4000 m³/h at 120 Pa, fan power 1.19 kW, max. gas (G20) consumption 4.55 m³/h, weight 102 kg, 2 year WARRANTY
EOLO NBC 45 AC MIX
28-43 kW modulating heat output, air flow 4000 m³/h at 120 Pa, fan power 1.19 kW, max. gas (G20) consumption 4.55 m³/h, weight 102 kg, 2 year WARRANTY
EOLO NBC 55 AC MIX 34-52 kW modulating heat output, air flow 5100 m³/h at 120 Pa, fan power 1.29 kW, max. gas (G20) consumption 5.5 m³/h, weight 136 kg, 2 year WARRANTY
EOLO NBC 55 AC MIX
34-52 kW modulating heat output, air flow 5100 m³/h at 120 Pa, fan power 1.29 kW, max. gas (G20) consumption 5.5 m³/h, weight 136 kg, 2 year WARRANTY
EOLO NBC 65 AC MIX 42-63 kW modulating heat output, air flow 5800 m³/h at 120 Pa, fan power 1.12 kW, max. gas (G20) consumption 6.67 m³/h, weight 148 kg, 2 year WARRANTY
EOLO NBC 65 AC MIX
42-63 kW modulating heat output, air flow 5800 m³/h at 120 Pa, fan power 1.12 kW, max. gas (G20) consumption 6.67 m³/h, weight 148 kg, 2 year WARRANTY
EOLO NBC 85 AC MIX 56-86 kW modulating heat output, air flow 8100 m³/h at 120 Pa, fan power 2.26 kW, max. gas (G20) consumption 9.1 m³/h, weight 172 kg, 2 year WARRANTY
EOLO NBC 85 AC MIX
56-86 kW modulating heat output, air flow 8100 m³/h at 120 Pa, fan power 2.26 kW, max. gas (G20) consumption 9.1 m³/h, weight 172 kg, 2 year WARRANTY
EOLO NBC 100 AC MIX 71-105 kW modulating heat output, air flow 9600 m³/h at 120 Pa, fan power 2.58 kW, max. gas (G20) consumption 11.11 m³/h, weight 212 kg, 2 year WARRANTY
EOLO NBC 100 AC MIX
71-105 kW modulating heat output, air flow 9600 m³/h at 120 Pa, fan power 2.58 kW, max. gas (G20) consumption 11.11 m³/h, weight 212 kg, 2 year WARRANTY
EOLO BC AC MIX - for external installation on wall or roof, fully insulated casing, condensing version, with centrifugal fan for ducts system, pre-mix burner
EOLO BC 25 AC MIX 8-22 kW modulating heat output, air flow 2200 m³/h at 120 Pa, fan power 0.54 kW, max. gas (G20) consumption 2.33 m³/h, weight 75 kg, 2 year WARRANTY
EOLO BC 25 AC MIX
8-22 kW modulating heat output, air flow 2200 m³/h at 120 Pa, fan power 0.54 kW, max. gas (G20) consumption 2.33 m³/h, weight 75 kg, 2 year WARRANTY
EOLO BC 35 AC MIX 11-32 kW modulating heat output, air flow 2800 m³/h at 120 Pa, fan power 0.58 kW, max. gas (G20) consumption 3.39 m³/h, weight 86 kg, 2 year WARRANTY
EOLO BC 35 AC MIX
11-32 kW modulating heat output, air flow 2800 m³/h at 120 Pa, fan power 0.58 kW, max. gas (G20) consumption 3.39 m³/h, weight 86 kg, 2 year WARRANTY
EOLO BC 45 AC MIX 15-43 kW modulating heat output, air flow 4000 m³/h at 120 Pa, fan power 1.19 kW, max. gas (G20) consumption 4.55 m³/h, weight 102 kg, 2 year WARRANTY
EOLO BC 45 AC MIX
15-43 kW modulating heat output, air flow 4000 m³/h at 120 Pa, fan power 1.19 kW, max. gas (G20) consumption 4.55 m³/h, weight 102 kg, 2 year WARRANTY
EOLO BC 55 AC MIX 18-52 kW modulating heat output, air flow 5100 m³/h at 120 Pa, fan power 1.29 kW, max. gas (G20) consumption 5.5 m³/h, weight 136 kg, 2 year WARRANTY
EOLO BC 55 AC MIX
18-52 kW modulating heat output, air flow 5100 m³/h at 120 Pa, fan power 1.29 kW, max. gas (G20) consumption 5.5 m³/h, weight 136 kg, 2 year WARRANTY
EOLO BC 65 AC MIX 22-63 kW modulating heat output, air flow 5800 m³/h at 120 Pa, fan power 1.12 kW, max. gas (G20) consumption 6.67 m³/h, weight 148 kg, 2 year WARRANTY
EOLO BC 65 AC MIX
22-63 kW modulating heat output, air flow 5800 m³/h at 120 Pa, fan power 1.12 kW, max. gas (G20) consumption 6.67 m³/h, weight 148 kg, 2 year WARRANTY
EOLO BC 85 AC MIX 28-86 kW modulating heat output, air flow 8100 m³/h at 120 Pa, fan power 2.26 kW, max. gas (G20) consumption 9.1 m³/h, weight 172 kg, 2 year WARRANTY
EOLO BC 85 AC MIX
28-86 kW modulating heat output, air flow 8100 m³/h at 120 Pa, fan power 2.26 kW, max. gas (G20) consumption 9.1 m³/h, weight 172 kg, 2 year WARRANTY
EOLO BC 100 AC MIX 32-103 kW modulating heat output, air flow 9600 m³/h at 120 Pa, fan power 2.58 kW, max. gas (G20) consumption 11.11 m³/h, weight 212 kg, 2 year WARRANTY
EOLO BC 100 AC MIX
32-103 kW modulating heat output, air flow 9600 m³/h at 120 Pa, fan power 2.58 kW, max. gas (G20) consumption 11.11 m³/h, weight 212 kg, 2 year WARRANTY
EOLO BC MIX external condensing gas fired heaters
Manuals 3.2 MB
Declarations of conformity 4.4 MB
Brochures 3.5 MB
Control panel user instructions 413 KB
Control panel manual 841 KB
AutoCAD drawings 10.5 MB
EOLO NBC MIX external non-condensing gas fired heaters
Manuals 6.6 MB
Declarations of conformity 4.4 MB
Brochures 3.5 MB
Control panel user instructions 413 KB
Control panel manual 841 KB
AutoCAD drawings 10.5 MB
SCM850 control panel
Manuals 751 KB
MODBUS protocol for connection to BMS 241 KB