GU - Cantilevered, for air flow regulation in ventilation systems, made of galvanized steel, manual adjustment with flat screwdriver, usually installed in spiral ducts | |||
---|---|---|---|
![]() |
GU/125x75 | Installation hole dimensions 125x75 mm, damper dimensions 115x65 mm | |
![]() |
GU/125x75 | ||
Installation hole dimensions 125x75 mm, damper dimensions 115x65 mm | |||
GU/225x75 | Installation hole dimensions 225x75 mm, damper dimensions 215x65 mm | ||
![]() |
GU/225x75 | ||
Installation hole dimensions 225x75 mm, damper dimensions 215x65 mm | |||
GU/325x75 | Installation hole dimensions 325x75 mm, damper dimensions 315x65 mm | ||
![]() |
GU/325x75 | ||
Installation hole dimensions 325x75 mm, damper dimensions 315x65 mm | |||
GU/425x75 | Installation hole dimensions 425x75 mm, damper dimensions 415x65 mm | ||
![]() |
GU/425x75 | ||
Installation hole dimensions 425x75 mm, damper dimensions 415x65 mm | |||
GU/525x75 | Installation hole dimensions 525x75 mm, damper dimensions 515x65 mm | ||
![]() |
GU/525x75 | ||
Installation hole dimensions 525x75 mm, damper dimensions 515x65 mm | |||
GU/625x75 | Installation hole dimensions 625x75 mm, damper dimensions 615x65 mm | ||
![]() |
GU/625x75 | ||
Installation hole dimensions 625x75 mm, damper dimensions 615x65 mm | |||
GU/825x75 | Installation hole dimensions 825x75 mm, damper dimensions 815x65 mm | ||
![]() |
GU/825x75 | ||
Installation hole dimensions 825x75 mm, damper dimensions 815x65 mm | |||
GU/1025x75 | Installation hole dimensions 1025x75 mm, damper dimensions 1015x65 mm | ||
![]() |
GU/1025x75 | ||
Installation hole dimensions 1025x75 mm, damper dimensions 1015x65 mm | |||
GU/1225x75 | Installation hole dimensions 1225x75 mm, damper dimensions 1215x65 mm | ||
![]() |
GU/1225x75 | ||
Installation hole dimensions 1225x75 mm, damper dimensions 1215x65 mm | |||
GU/125x125 | Installation hole dimensions 125x125 mm, damper dimensions 115x115 mm | ||
![]() |
GU/125x125 | ||
Installation hole dimensions 125x125 mm, damper dimensions 115x115 mm | |||
GU/225x125 | Installation hole dimensions 225x125 mm, damper dimensions 215x115 mm | ||
![]() |
GU/225x125 | ||
Installation hole dimensions 225x125 mm, damper dimensions 215x115 mm | |||
GU/325x125 | Installation hole dimensions 325x125 mm, damper dimensions 315x115 mm | ||
![]() |
GU/325x125 | ||
Installation hole dimensions 325x125 mm, damper dimensions 315x115 mm | |||
GU/425x125 | Installation hole dimensions 425x125 mm, damper dimensions 415x115 mm | ||
![]() |
GU/425x125 | ||
Installation hole dimensions 425x125 mm, damper dimensions 415x115 mm | |||
GU/525x125 | Installation hole dimensions 525x125 mm, damper dimensions 515x115 mm | ||
![]() |
GU/525x125 | ||
Installation hole dimensions 525x125 mm, damper dimensions 515x115 mm | |||
GU/625x125 | Installation hole dimensions 625x125 mm, damper dimensions 615x115 mm | ||
![]() |
GU/625x125 | ||
Installation hole dimensions 625x125 mm, damper dimensions 615x115 mm | |||
GU/825x125 | Installation hole dimensions 825x125 mm, damper dimensions 815x115 mm | ||
![]() |
GU/825x125 | ||
Installation hole dimensions 825x125 mm, damper dimensions 815x115 mm | |||
GU/1025x125 | Installation hole dimensions 1025x125 mm, damper dimensions 1015x115 mm | ||
![]() |
GU/1025x125 | ||
Installation hole dimensions 1025x125 mm, damper dimensions 1015x115 mm | |||
GU/1225x125 | Installation hole dimensions 1225x125 mm, damper dimensions 1215x115 mm | ||
![]() |
GU/1225x125 | ||
Installation hole dimensions 1225x125 mm, damper dimensions 1215x115 mm | |||
GU/225x225 | Installation hole dimensions 225x225 mm, damper dimensions 215x215 mm | ||
![]() |
GU/225x225 | ||
Installation hole dimensions 225x225 mm, damper dimensions 215x215 mm | |||
GU/325x225 | Installation hole dimensions 325x225 mm, damper dimensions 315x215 mm | ||
![]() |
GU/325x225 | ||
Installation hole dimensions 325x225 mm, damper dimensions 315x215 mm | |||
GU/425x225 | Installation hole dimensions 425x225 mm, damper dimensions 415x215 mm | ||
![]() |
GU/425x225 | ||
Installation hole dimensions 425x225 mm, damper dimensions 415x215 mm | |||
GU/525x225 | Installation hole dimensions 525x225 mm, damper dimensions 515x215 mm | ||
![]() |
GU/525x225 | ||
Installation hole dimensions 525x225 mm, damper dimensions 515x215 mm | |||
GU/625x225 | Installation hole dimensions 625x225 mm, damper dimensions 615x215 mm | ||
![]() |
GU/625x225 | ||
Installation hole dimensions 625x225 mm, damper dimensions 615x215 mm | |||
GU/825x225 | Installation hole dimensions 825x225 mm, damper dimensions 815x215 mm | ||
![]() |
GU/825x225 | ||
Installation hole dimensions 825x225 mm, damper dimensions 815x215 mm | |||
GU/1025x225 | Installation hole dimensions 1025x225 mm, damper dimensions 1015x215 mm | ||
![]() |
GU/1025x225 | ||
Installation hole dimensions 1025x225 mm, damper dimensions 1015x215 mm | |||
GU/1225x225 | Installation hole dimensions 1225x225 mm, damper dimensions 1215x215 mm | ||
![]() |
GU/1225x225 | ||
Installation hole dimensions 1225x225 mm, damper dimensions 1215x215 mm | |||
GU/325x325 | Installation hole dimensions 325x325 mm, damper dimensions 315x315 mm | ||
![]() |
GU/325x325 | ||
Installation hole dimensions 325x325 mm, damper dimensions 315x315 mm | |||
GU/425x325 | Installation hole dimensions 425x325 mm, damper dimensions 415x315 mm | ||
![]() |
GU/425x325 | ||
Installation hole dimensions 425x325 mm, damper dimensions 415x315 mm | |||
GU/525x325 | Installation hole dimensions 525x325 mm, damper dimensions 515x315 mm | ||
![]() |
GU/525x325 | ||
Installation hole dimensions 525x325 mm, damper dimensions 515x315 mm | |||
GU/625x325 | Installation hole dimensions 625x325 mm, damper dimensions 615x315 mm | ||
![]() |
GU/625x325 | ||
Installation hole dimensions 625x325 mm, damper dimensions 615x315 mm | |||
GU/825x325 | Installation hole dimensions 825x325 mm, damper dimensions 815x315 mm | ||
![]() |
GU/825x325 | ||
Installation hole dimensions 825x325 mm, damper dimensions 815x315 mm | |||
GU/1025x325 | Installation hole dimensions 1025x325 mm, damper dimensions 1015x315 mm | ||
![]() |
GU/1025x325 | ||
Installation hole dimensions 1025x325 mm, damper dimensions 1015x315 mm | |||
GU/1225x325 | Installation hole dimensions 1225x325 mm, damper dimensions 1215x315 mm | ||
![]() |
GU/1225x325 | ||
Installation hole dimensions 1225x325 mm, damper dimensions 1215x315 mm | |||
GU/425x425 | Installation hole dimensions 425x425 mm, damper dimensions 415x415 mm | ||
![]() |
GU/425x425 | ||
Installation hole dimensions 425x425 mm, damper dimensions 415x415 mm | |||
GU/525x425 | Installation hole dimensions 525x425 mm, damper dimensions 515x415 mm | ||
![]() |
GU/525x425 | ||
Installation hole dimensions 525x425 mm, damper dimensions 515x415 mm | |||
GU/625x425 | Installation hole dimensions 625x425 mm, damper dimensions 615x415 mm | ||
![]() |
GU/625x425 | ||
Installation hole dimensions 625x425 mm, damper dimensions 615x415 mm | |||
GU/825x425 | Installation hole dimensions 825x425 mm, damper dimensions 815x415 mm | ||
![]() |
GU/825x425 | ||
Installation hole dimensions 825x425 mm, damper dimensions 815x415 mm | |||
GU/1025x425 | Installation hole dimensions 1025x425 mm, damper dimensions 1015x415 mm | ||
![]() |
GU/1025x425 | ||
Installation hole dimensions 1025x425 mm, damper dimensions 1015x415 mm | |||
GU/1225x425 | Installation hole dimensions 1225x425 mm, damper dimensions 1215x415 mm | ||
![]() |
GU/1225x425 | ||
Installation hole dimensions 1225x425 mm, damper dimensions 1215x415 mm | |||
GU/525x525 | Installation hole dimensions 525x525 mm, damper dimensions 515x515 mm | ||
![]() |
GU/525x525 | ||
Installation hole dimensions 525x525 mm, damper dimensions 515x515 mm | |||
GU/625x525 | Installation hole dimensions 625x525 mm, damper dimensions 615x515 mm | ||
![]() |
GU/625x525 | ||
Installation hole dimensions 625x525 mm, damper dimensions 615x515 mm | |||
GU/825x525 | Installation hole dimensions 825x525 mm, damper dimensions 815x515 mm | ||
![]() |
GU/825x525 | ||
Installation hole dimensions 825x525 mm, damper dimensions 815x515 mm | |||
GU/1025x525 | Installation hole dimensions 1025x525 mm, damper dimensions 1015x515 mm | ||
![]() |
GU/1025x525 | ||
Installation hole dimensions 1025x525 mm, damper dimensions 1015x515 mm | |||
GU/1225x525 | Installation hole dimensions 1225x525 mm, damper dimensions 1215x515 mm | ||
![]() |
GU/1225x525 | ||
Installation hole dimensions 1225x525 mm, damper dimensions 1215x515 mm | |||
GU/625x625 | Installation hole dimensions 625x625 mm, damper dimensions 615x615 mm | ||
![]() |
GU/625x625 | ||
Installation hole dimensions 625x625 mm, damper dimensions 615x615 mm | |||
GU/825x625 | Installation hole dimensions 825x625 mm, damper dimensions 815x615 mm | ||
![]() |
GU/825x625 | ||
Installation hole dimensions 825x625 mm, damper dimensions 815x615 mm | |||
GU/1025x625 | Installation hole dimensions 1025x625 mm, damper dimensions 1015x615 mm | ||
![]() |
GU/1025x625 | ||
Installation hole dimensions 1025x625 mm, damper dimensions 1015x615 mm | |||
GU/1225x625 | Installation hole dimensions 1225x625 mm, damper dimensions 1215x615 mm | ||
![]() |
GU/1225x625 | ||
Installation hole dimensions 1225x625 mm, damper dimensions 1215x615 mm |
Cantilevered damper GU is used to regulate the flow of air in the ventilation grilles in the medium and low-pressure ventilation instalation. The damper is adjustable manually, using a flat screwdriver. Especially it recommended for installation on spiral channels.
Damper has Hygienic Certificate HK/K/0522/03/2016
Material and workmanship
The damper is made of galvanized steel. On request it is possible to make from aluminum and stainless steel (type 1.4301 or 1.4404).