Heating power at 60/40°C water and 18°C air temperature: from 8.1 kW at min. airflow to 12.9 kW at max. airflow, temperature increase ΔT 26-21°C, 3 row heat exchanger, air flow 900-1800 m³/h, max. electrical power consumption 270 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 38.5 kg, 2 year WARRANTY |
|
ELiS AX36-W3R-100
|
Heating power at 60/40°C water and 18°C air temperature: from 8.1 kW at min. airflow to 12.9 kW at max. airflow, temperature increase ΔT 26-21°C, 3 row heat exchanger, air flow 900-1800 m³/h, max. electrical power consumption 270 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 38.5 kg, 2 year WARRANTY |
ELiS AX36-W3R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 11.8 kW at min. airflow to 20.5 kW at max. airflow, temperature increase ΔT 29-22°C, 3 row heat exchanger, air flow 1200-2700 m³/h, max. electrical power consumption 400 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 53.3 kg, 2 year WARRANTY |
|
ELiS AX36-W3R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 11.8 kW at min. airflow to 20.5 kW at max. airflow, temperature increase ΔT 29-22°C, 3 row heat exchanger, air flow 1200-2700 m³/h, max. electrical power consumption 400 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 53.3 kg, 2 year WARRANTY |
ELiS AX36-W3R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 17.1 kW at min. airflow to 29.0 kW at max. airflow, temperature increase ΔT 25-20°C, 3 row heat exchanger, air flow 2000-4300 m³/h, max. electrical power consumption 670 W, acoustic pressure level 45-63 dB(A), covered door gap 2 m, weight 71.7 kg, 2 year WARRANTY |
|
ELiS AX36-W3R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 17.1 kW at min. airflow to 29.0 kW at max. airflow, temperature increase ΔT 25-20°C, 3 row heat exchanger, air flow 2000-4300 m³/h, max. electrical power consumption 670 W, acoustic pressure level 45-63 dB(A), covered door gap 2 m, weight 71.7 kg, 2 year WARRANTY |
ELiS AX36-W3R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 21.4 kW at min. airflow to 38.0 kW at max. airflow, temperature increase ΔT 27-21°C, 3 row heat exchanger, air flow 2300-5300 m³/h, max. electrical power consumption 810 W, acoustic pressure level 46-64 dB(A), covered door gap 2.5 m, weight 86.8 kg, 2 year WARRANTY |
|
ELiS AX36-W3R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 21.4 kW at min. airflow to 38.0 kW at max. airflow, temperature increase ΔT 27-21°C, 3 row heat exchanger, air flow 2300-5300 m³/h, max. electrical power consumption 810 W, acoustic pressure level 46-64 dB(A), covered door gap 2.5 m, weight 86.8 kg, 2 year WARRANTY |
ELiS AX36-W4R-100
|
Heating power at 60/40°C water and 18°C air temperature: from 8.7 kW at min. airflow to 15.2 kW at max. airflow, temperature increase ΔT 32-26°C, 4 row heat exchanger, air flow 800-1700 m³/h, max. electrical power consumption 270 W, acoustic pressure level 41-59 dB(A), covered door gap 1 m, weight 40.0 kg, 2 year WARRANTY |
|
ELiS AX36-W4R-100
|
Heating power at 60/40°C water and 18°C air temperature: from 8.7 kW at min. airflow to 15.2 kW at max. airflow, temperature increase ΔT 32-26°C, 4 row heat exchanger, air flow 800-1700 m³/h, max. electrical power consumption 270 W, acoustic pressure level 41-59 dB(A), covered door gap 1 m, weight 40.0 kg, 2 year WARRANTY |
ELiS AX36-W4R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 12.7 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 34-27°C, 4 row heat exchanger, air flow 1100-2600 m³/h, max. electrical power consumption 400 W, acoustic pressure level 42-60 dB(A), covered door gap 1.5 m, weight 55.6 kg, 2 year WARRANTY |
|
ELiS AX36-W4R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 12.7 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 34-27°C, 4 row heat exchanger, air flow 1100-2600 m³/h, max. electrical power consumption 400 W, acoustic pressure level 42-60 dB(A), covered door gap 1.5 m, weight 55.6 kg, 2 year WARRANTY |
ELiS AX36-W4R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 20.6 kW at min. airflow to 36.7 kW at max. airflow, temperature increase ΔT 31-26°C, 4 row heat exchanger, air flow 1900-4200 m³/h, max. electrical power consumption 670 W, acoustic pressure level 44-62 dB(A), covered door gap 2 m, weight 74.8 kg, 2 year WARRANTY |
|
ELiS AX36-W4R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 20.6 kW at min. airflow to 36.7 kW at max. airflow, temperature increase ΔT 31-26°C, 4 row heat exchanger, air flow 1900-4200 m³/h, max. electrical power consumption 670 W, acoustic pressure level 44-62 dB(A), covered door gap 2 m, weight 74.8 kg, 2 year WARRANTY |
ELiS AX36-W4R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 24.7 kW at min. airflow to 46.6 kW at max. airflow, temperature increase ΔT 33-26°C, 4 row heat exchanger, air flow 2200-5200 m³/h, max. electrical power consumption 810 W, acoustic pressure level 45-63 dB(A), covered door gap 2.5 m, weight 90.3 kg, 2 year WARRANTY |
|
ELiS AX36-W4R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 24.7 kW at min. airflow to 46.6 kW at max. airflow, temperature increase ΔT 33-26°C, 4 row heat exchanger, air flow 2200-5200 m³/h, max. electrical power consumption 810 W, acoustic pressure level 45-63 dB(A), covered door gap 2.5 m, weight 90.3 kg, 2 year WARRANTY |
|
ELiS AX45-W3R-100
|
Heating power at 60/40°C water and 18°C air temperature: from 9.3 kW at min. airflow to 15.7 kW at max. airflow, temperature increase ΔT 25-18°C, 3 row heat exchanger, air flow 1100-2500 m³/h, max. electrical power consumption 490 W, acoustic pressure level 43-61 dB(A), covered door gap 1 m, weight 40.8 kg, 2 year WARRANTY |
|
ELiS AX45-W3R-100
|
Heating power at 60/40°C water and 18°C air temperature: from 9.3 kW at min. airflow to 15.7 kW at max. airflow, temperature increase ΔT 25-18°C, 3 row heat exchanger, air flow 1100-2500 m³/h, max. electrical power consumption 490 W, acoustic pressure level 43-61 dB(A), covered door gap 1 m, weight 40.8 kg, 2 year WARRANTY |
ELiS AX45-W3R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 13.9 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 1500-3500 m³/h, max. electrical power consumption 650 W, acoustic pressure level 44-62 dB(A), covered door gap 1.5 m, weight 55.5 kg, 2 year WARRANTY |
|
ELiS AX45-W3R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 13.9 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 1500-3500 m³/h, max. electrical power consumption 650 W, acoustic pressure level 44-62 dB(A), covered door gap 1.5 m, weight 55.5 kg, 2 year WARRANTY |
ELiS AX45-W3R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 18.4 kW at min. airflow to 31.8 kW at max. airflow, temperature increase ΔT 24-19°C, 3 row heat exchanger, air flow 2200-5000 m³/h, max. electrical power consumption 990 W, acoustic pressure level 45-64 dB(A), covered door gap 2 m, weight 73.7 kg, 2 year WARRANTY |
|
ELiS AX45-W3R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 18.4 kW at min. airflow to 31.8 kW at max. airflow, temperature increase ΔT 24-19°C, 3 row heat exchanger, air flow 2200-5000 m³/h, max. electrical power consumption 990 W, acoustic pressure level 45-64 dB(A), covered door gap 2 m, weight 73.7 kg, 2 year WARRANTY |
ELiS AX45-W3R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 22.1 kW at min. airflow to 41.4 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 2400-6100 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 46-65 dB(A), covered door gap 2.5 m, weight 88.8 kg, 2 year WARRANTY |
|
ELiS AX45-W3R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 22.1 kW at min. airflow to 41.4 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 2400-6100 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 46-65 dB(A), covered door gap 2.5 m, weight 88.8 kg, 2 year WARRANTY |
ELiS AX45-W4R-100
|
Heating power at 60/40°C water and 18°C air temperature: from 10.3 kW at min. airflow to 19.1 kW at max. airflow, temperature increase ΔT 30-23°C, 4 row heat exchanger, air flow 1000-2400 m³/h, max. electrical power consumption 490 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 42.3 kg, 2 year WARRANTY |
|
ELiS AX45-W4R-100
|
Heating power at 60/40°C water and 18°C air temperature: from 10.3 kW at min. airflow to 19.1 kW at max. airflow, temperature increase ΔT 30-23°C, 4 row heat exchanger, air flow 1000-2400 m³/h, max. electrical power consumption 490 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 42.3 kg, 2 year WARRANTY |
ELiS AX45-W4R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 15.3 kW at min. airflow to 28.9 kW at max. airflow, temperature increase ΔT 32-25°C, 4 row heat exchanger, air flow 1400-3400 m³/h, max. electrical power consumption 650 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 57.8 kg, 2 year WARRANTY |
|
ELiS AX45-W4R-150
|
Heating power at 60/40°C water and 18°C air temperature: from 15.3 kW at min. airflow to 28.9 kW at max. airflow, temperature increase ΔT 32-25°C, 4 row heat exchanger, air flow 1400-3400 m³/h, max. electrical power consumption 650 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 57.8 kg, 2 year WARRANTY |
ELiS AX45-W4R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 22.2 kW at min. airflow to 40.6 kW at max. airflow, temperature increase ΔT 31-24°C, 4 row heat exchanger, air flow 2100-4900 m³/h, max. electrical power consumption 990 W, acoustic pressure level 44-63 dB(A), covered door gap 2 m, weight 76.8 kg, 2 year WARRANTY |
|
ELiS AX45-W4R-200
|
Heating power at 60/40°C water and 18°C air temperature: from 22.2 kW at min. airflow to 40.6 kW at max. airflow, temperature increase ΔT 31-24°C, 4 row heat exchanger, air flow 2100-4900 m³/h, max. electrical power consumption 990 W, acoustic pressure level 44-63 dB(A), covered door gap 2 m, weight 76.8 kg, 2 year WARRANTY |
ELiS AX45-W4R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 25.6 kW at min. airflow to 51.3 kW at max. airflow, temperature increase ΔT 33-25°C, 4 row heat exchanger, air flow 2300-6000 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 45-64 dB(A), covered door gap 2.5 m, weight 92.3 kg, 2 year WARRANTY |
|
ELiS AX45-W4R-250
|
Heating power at 60/40°C water and 18°C air temperature: from 25.6 kW at min. airflow to 51.3 kW at max. airflow, temperature increase ΔT 33-25°C, 4 row heat exchanger, air flow 2300-6000 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 45-64 dB(A), covered door gap 2.5 m, weight 92.3 kg, 2 year WARRANTY |