Water air curtain, horizontal and vertical mounting, 3 step fan, protection class IP20, mounting height up to 3.5 m, built in control system (motion sensor, water valve switch, 2 selected fan steps switch), very thin - only 189 mm in height, heating capacity: from 5.4 kW (50/40°C) to 13.8 kW (90/70°C), air flow 770/880/1050 m³/h, fan power 63/72/97 W, sound pressure level 45/50/55 dB(A), length 1 m, weight 17.3 kg, black color, 2 year WARRANTY
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Model: SLIM W-100 2R BLACK
General data
Heating capacity at 90/70°C water and 10°C air temperature, fan at max speed
kW
13,8
Heating capacity at 50/40°C water and 10°C air temperature, fan at min speed
kW
5,4
Air flow range
m
3,5
Max. air flow
m³/h
1050
Fan data
Steps
3
Fan data at 3rd (max) speed
Air flow
m³/h
1050
Air flow with filter (Coarse 30%)
m³/h
650
Air flow range
m
3,5
Power consumption
W
97
Current consumption
A
0,4
Acoustic pressure level at a distance of 3 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
56
Acoustic pressure level at a distance of 5 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
55
Acoustic power level according to ISO 27327-2
dB(A)
70
Fan data at 2nd (mid) speed
Air flow
m³/h
880
Air flow with filter (Coarse 30%)
m³/h
620
Air flow range
m
2,5
Power consumption
W
72
Current consumption
A
0,3
Acoustic pressure level at a distance of 3 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
51
Acoustic pressure level at a distance of 5 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
50
Acoustic power level according to ISO 27327-2
dB(A)
66
Fan data at 1st (min) speed
Air flow
m³/h
770
Air flow with filter (Coarse 30%)
m³/h
550
Air flow range
m
1,8
Power consumption
W
63
Current consumption
A
0,25
Acoustic pressure level at a distance of 3 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
46
Acoustic pressure level at a distance of 5 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
45
Acoustic power level according to ISO 27327-2
dB(A)
61
Installation data
Power supply
V/Hz
1N ~ 230/50
IP protection class
20
Installation
Horizontal / vertical
Max. heating water temperature
°C
110
Max. operating pressure
MPa
1,6
Hydraulic connection
Ø "
½
Max. mounting height
m
3,5
Other data
Color
Black
Dimensions
Length
mm
1000
Depth
mm
399
Height
mm
189
Weight without water
kg
17,3
Weight of unit filled with water
kg
18,4

Dimensions

Model: SLIM W-100 2R BLACK

Heating capacity tables

SLIM W-100 2R BLACK airflow on 3 speed = 1050 m³/h
Tp1
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
 
0
5
10
15
20
Tw1/Tw2 = 110/90°C
20,4
908
6,8
57,5
19,4
863
6,2
59,5
18,4
819
5,6
61,5
17,4
775
5,1
63,5
16,4
731
4,6
65,5
 
0
5
10
15
20
Tw1/Tw2 = 90/70°C
15,9
700
4,5
45,0
14,9
656
4,0
47,0
13,8
611
3,5
49,0
12,8
566
3,0
51,0
11,8
522
2,6
53,0
 
0
5
10
15
20
Tw1/Tw2 = 80/60°C
13,6
598
3,5
38,5
12,6
553
3,0
40,5
11,6
508
2,6
42,5
10,5
463
2,2
44,5
9,5
417
1,8
46,5
 
0
5
10
15
20
Tw1/Tw2 = 70/50°C
11,3
495
2,6
32,0
10,3
450
2,2
34,0
9,2
404
1,8
36,0
8,2
359
1,4
38,0
7,1
312
1,1
40,0
 
0
5
10
15
20
Tw1/Tw2 = 60/40°C
9,0
392
1,8
25,5
7,9
346
1,4
27,5
6,9
299
1,1
29,5
5,8
251
0,8
31,0
4,6
201
0,5
33,0
 
0
5
10
15
20
Tw1/Tw2 = 50/40°C
8,8
761
5,8
25,0
7,7
671
4,7
27,0
6,7
580
3,6
29,0
5,6
488
2,6
30,5
4,5
395
1,8
32,5
SLIM W-100 2R BLACK airflow on 2 speed = 880 m³/h
Tp1
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
 
0
5
10
15
20
Tw1/Tw2 = 110/90°C
18,0
803
5,4
61,0
17,1
763
5,0
62,5
16,3
724
4,5
64,5
15,4
685
4,1
66,5
14,5
647
3,7
68,0
 
0
5
10
15
20
Tw1/Tw2 = 90/70°C
14,0
620
3,6
47,5
13,1
580
3,2
49,5
12,3
541
2,8
51,0
11,4
501
2,4
53,0
10,5
462
2,1
54,5
 
0
5
10
15
20
Tw1/Tw2 = 80/60°C
12,0
529
2,8
40,5
11,1
489
2,4
42,5
10,2
449
2,1
44,5
9,3
410
1,8
46,0
8,4
370
1,5
48,0
 
0
5
10
15
20
Tw1/Tw2 = 70/50°C
10,0
438
2,1
34,0
9,1
398
1,7
35,5
8,2
358
1,4
37,5
7,3
317
1,2
39,5
6,3
276
0,9
41,0
 
0
5
10
15
20
Tw1/Tw2 = 60/40°C
8,0
346
1,4
27,0
7,0
306
1,1
28,5
6,1
264
0,9
30,5
5,1
221
0,6
32,0
4,0
176
0,4
33,5
 
0
5
10
15
20
Tw1/Tw2 = 50/40°C
7,7
673
4,7
26,0
6,8
593
3,7
28,0
5,9
513
2,9
30,0
5,0
432
2,1
31,5
4,0
350
1,5
33,5
SLIM W-100 2R BLACK airflow on 1 speed = 770 m³/h
Tp1
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
PT
Qw
∆pw
Tp2
kW
l/h
kPa
°C
 
0
5
10
15
20
Tw1/Tw2 = 110/90°C
16,4
732
4,6
63,5
15,6
697
4,2
65,0
14,8
661
3,8
66,5
14,0
625
3,4
68,5
13,3
590
3,1
70,0
 
0
5
10
15
20
Tw1/Tw2 = 90/70°C
12,8
566
3,0
49,5
12,0
529
2,7
51,0
11,2
493
2,4
53,0
10,4
457
2,1
54,5
9,6
422
1,8
56,0
 
0
5
10
15
20
Tw1/Tw2 = 80/60°C
11,0
483
2,4
42,5
10,2
447
2,1
44,0
9,3
410
1,8
46,0
8,5
374
1,5
47,5
7,7
337
1,2
49,0
 
0
5
10
15
20
Tw1/Tw2 = 70/50°C
9,1
400
1,7
35,5
8,3
364
1,5
37,0
7,5
327
1,2
38,5
6,6
290
1,0
40,5
5,8
252
0,8
42,0
 
0
5
10
15
20
Tw1/Tw2 = 60/40°C
7,3
316
1,2
28,0
6,4
279
1,0
29,5
5,5
241
0,7
31,0
4,6
201
0,5
32,5
3,6
158
0,4
34,0
 
0
5
10
15
20
Tw1/Tw2 = 50/40°C
7,1
614
4,0
27,5
6,2
541
3,2
29,0
5,4
468
2,5
30,5
4,5
394
1,8
32,5
3,7
319
1,2
34,0
  • PT - heating capacity
  • Tp1 - air temperature at the unit inlet
  • Tp2 - air temperature at the unit outlet
  • Tw1 - heating medium temperature at the heat exchanger inlet
  • Tw2 - heating medium temperature at the heat exchanger outlet
  • Qw - heating medium flow rate in heat exchanger
  • Δpw - heating medium pressure drop in heat exchanger

If you want to calculate heating capacity at different parameters you can do this at manufacturer website.