Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
NEXT-G series - condensing, with fixed airflow axial AC fan for direct horizontal blowing, pre-mix burner, heat output modulation from 100% to 30%, can be connected to BMS via Modbus RTU protocol
NEXT-G 20 8.5-19.0 kW modulating heat output, air flow 2300 m³/h, air throw 15 m, electrical power absorbtion 0.20 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 20
8.5-19.0 kW modulating heat output, air flow 2300 m³/h, air throw 15 m, electrical power absorbtion 0.20 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 30 9.9-27.4 kW modulating heat output, air flow 2450 m³/h, air throw 18 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 30
9.9-27.4 kW modulating heat output, air flow 2450 m³/h, air throw 18 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 35 13.1-33.4 kW modulating heat output, air flow 2700 m³/h, air throw 20 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 35
13.1-33.4 kW modulating heat output, air flow 2700 m³/h, air throw 20 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 45 14.5-41.4 kW modulating heat output, air flow 3450 m³/h, air throw 24 m, electrical power absorbtion 0.35 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 45
14.5-41.4 kW modulating heat output, air flow 3450 m³/h, air throw 24 m, electrical power absorbtion 0.35 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 60 19.5-56.6 kW modulating heat output, air flow 5650 m³/h, air throw 28 m, electrical power absorbtion 0.61 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 60
19.5-56.6 kW modulating heat output, air flow 5650 m³/h, air throw 28 m, electrical power absorbtion 0.61 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 90 28.6-87.3 kW modulating heat output, air flow 9100 m³/h, air throw 38 m, electrical power absorbtion 1.00 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
NEXT-G 90
28.6-87.3 kW modulating heat output, air flow 9100 m³/h, air throw 38 m, electrical power absorbtion 1.00 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
NEXT-G EC series - condensing, with modulating air flow axial EC fan for direct horizontal blowing, pre-mix burner, heat output modulation from 100% to 30%, can be connected to BMS via Modbus RTU protocol
NEXT-G 20 EC 8.5-19.0 kW modulating heat output, max. air flow 2300 m³/h, air throw 15 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 20 EC
8.5-19.0 kW modulating heat output, max. air flow 2300 m³/h, air throw 15 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 30 EC 9.9-27.4 kW modulating heat output, max. air flow 2450 m³/h, air throw 18 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 30 EC
9.9-27.4 kW modulating heat output, max. air flow 2450 m³/h, air throw 18 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 35 EC 13.1-33.4 kW modulating heat output, max. air flow 2735 m³/h, air throw 20 m, max. electrical power absorbtion 0.18 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 35 EC
13.1-33.4 kW modulating heat output, max. air flow 2735 m³/h, air throw 20 m, max. electrical power absorbtion 0.18 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 45 EC 14.5-41.4 kW modulating heat output, max. air flow 3450 m³/h, air throw 24 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 45 EC
14.5-41.4 kW modulating heat output, max. air flow 3450 m³/h, air throw 24 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 60 EC 19.5-56.6 kW modulating heat output, max. air flow 5650 m³/h, air throw 28 m, max. electrical power absorbtion 0.41 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 60 EC
19.5-56.6 kW modulating heat output, max. air flow 5650 m³/h, air throw 28 m, max. electrical power absorbtion 0.41 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 75 EC 26.3-72.0 kW modulating heat output, max. air flow 5400 m³/h, air throw 28 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 7.93 m³/h, weight 90 kg, 2 year WARRANTY
NEXT-G 75 EC
26.3-72.0 kW modulating heat output, max. air flow 5400 m³/h, air throw 28 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 7.93 m³/h, weight 90 kg, 2 year WARRANTY
NEXT-G 90 EC 28.6-87.3 kW modulating heat output, max. air flow 9100 m³/h, air throw 38 m, max. electrical power absorbtion 0.75 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
NEXT-G 90 EC
28.6-87.3 kW modulating heat output, max. air flow 9100 m³/h, air throw 38 m, max. electrical power absorbtion 0.75 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
NEXT-G condensing and modulating gas fired unit heaters
Manuals 15.6 MB
Catalogue 1.6 MB
MODBUS protocol for connection to BMS 155 KB
Re-Mote digital control panel
Manuals 3.5 MB