Gas heater, condensing, with fixed airflow axial AC fan for direct horizontal blowing, pre-mix burner, delivered with external room temperature probe and condensate drain siphon, heat output modulation from 100% to 30%, can be connected to BMS via Modbus RTU protocol, 19.5-56.6 kW modulating heat output, air flow 5650 m³/h, air throw 28 m, electrical power absorbtion 0.61 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
Interested in this product? Contact us:

Arvydas Palivonas

LT, RU, EN
+370 601 74426

Sales representative for Vilnius, Ukmergė, Utena, Kaišiadorys and Varėna regions Get Offer

Andrius Lekarevičius

LT, RU, EN
+370 606 11865

Sales representative for Kaunas, Panevėžys, Šiauliai, Telšiai, Klaipėda, Tauragė, Marijampolė and Alytus districts Get Offer
Click on the Model for technical data, dimensions, accessories
NEXT-G series - condensing, with fixed airflow axial AC fan for direct horizontal blowing, pre-mix burner, delivered with external room temperature probe and condensate drain siphon, heat output modulation from 100% to 30%, can be connected to BMS via Modbus RTU protocol
NEXT-G 20 8.5-19.0 kW modulating heat output, air flow 2300 m³/h, air throw 15 m, electrical power absorbtion 0.20 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 20
8.5-19.0 kW modulating heat output, air flow 2300 m³/h, air throw 15 m, electrical power absorbtion 0.20 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 30 9.9-27.4 kW modulating heat output, air flow 2450 m³/h, air throw 18 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 30
9.9-27.4 kW modulating heat output, air flow 2450 m³/h, air throw 18 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 35 13.1-33.4 kW modulating heat output, air flow 2700 m³/h, air throw 20 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 35
13.1-33.4 kW modulating heat output, air flow 2700 m³/h, air throw 20 m, electrical power absorbtion 0.21 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 45 14.5-41.4 kW modulating heat output, air flow 3450 m³/h, air throw 24 m, electrical power absorbtion 0.35 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 45
14.5-41.4 kW modulating heat output, air flow 3450 m³/h, air throw 24 m, electrical power absorbtion 0.35 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 60 19.5-56.6 kW modulating heat output, air flow 5650 m³/h, air throw 28 m, electrical power absorbtion 0.61 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 60
19.5-56.6 kW modulating heat output, air flow 5650 m³/h, air throw 28 m, electrical power absorbtion 0.61 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 90 28.6-87.3 kW modulating heat output, air flow 9100 m³/h, air throw 38 m, electrical power absorbtion 1.00 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
NEXT-G 90
28.6-87.3 kW modulating heat output, air flow 9100 m³/h, air throw 38 m, electrical power absorbtion 1.00 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
NEXT-G EC series - condensing, with modulating air flow axial EC fan for direct horizontal blowing, pre-mix burner, delivered with external room temperature probe and condensate drain siphon, heat output modulation from 100% to 30%, can be connected to BMS via Modbus RTU protocol
NEXT-G 20 EC 8.5-19.0 kW modulating heat output, max. air flow 2300 m³/h, air throw 15 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 20 EC
8.5-19.0 kW modulating heat output, max. air flow 2300 m³/h, air throw 15 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.07 m³/h, weight 35 kg, 2 year WARRANTY
NEXT-G 30 EC 9.9-27.4 kW modulating heat output, max. air flow 2450 m³/h, air throw 18 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 30 EC
9.9-27.4 kW modulating heat output, max. air flow 2450 m³/h, air throw 18 m, max. electrical power absorbtion 0.19 kW, max. gas (G20) consumption 2.97 m³/h, weight 56 kg, 2 year WARRANTY
NEXT-G 35 EC 13.1-33.4 kW modulating heat output, max. air flow 2735 m³/h, air throw 20 m, max. electrical power absorbtion 0.18 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 35 EC
13.1-33.4 kW modulating heat output, max. air flow 2735 m³/h, air throw 20 m, max. electrical power absorbtion 0.18 kW, max. gas (G20) consumption 3.66 m³/h, weight 58 kg, 2 year WARRANTY
NEXT-G 45 EC 14.5-41.4 kW modulating heat output, max. air flow 3450 m³/h, air throw 24 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 45 EC
14.5-41.4 kW modulating heat output, max. air flow 3450 m³/h, air throw 24 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 4.56 m³/h, weight 61 kg, 2 year WARRANTY
NEXT-G 60 EC 19.5-56.6 kW modulating heat output, max. air flow 5650 m³/h, air throw 28 m, max. electrical power absorbtion 0.41 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 60 EC
19.5-56.6 kW modulating heat output, max. air flow 5650 m³/h, air throw 28 m, max. electrical power absorbtion 0.41 kW, max. gas (G20) consumption 6.14 m³/h, weight 79 kg, 2 year WARRANTY
NEXT-G 75 EC 26.3-72.0 kW modulating heat output, max. air flow 5400 m³/h, air throw 28 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 7.93 m³/h, weight 90 kg, 2 year WARRANTY
NEXT-G 75 EC
26.3-72.0 kW modulating heat output, max. air flow 5400 m³/h, air throw 28 m, max. electrical power absorbtion 0.39 kW, max. gas (G20) consumption 7.93 m³/h, weight 90 kg, 2 year WARRANTY
NEXT-G 90 EC 28.6-87.3 kW modulating heat output, max. air flow 9100 m³/h, air throw 38 m, max. electrical power absorbtion 0.75 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
NEXT-G 90 EC
28.6-87.3 kW modulating heat output, max. air flow 9100 m³/h, air throw 38 m, max. electrical power absorbtion 0.75 kW, max. gas (G20) consumption 9.37 m³/h, weight 100 kg, 2 year WARRANTY
Model: NEXT-G 60
General data
Nominal heat output (min - max)
kW
18,5 - 58,0
Delivered thermal power (min. - max.)
kW
19,5 - 56,6
Efficiency (at min - max heating power)
%
105,2 - 97,5
Air flow range (measured horizontaly at 0.5 m/s speed limit)
m
28
Natural gas (G20) consumption
m³/h
6,14
LPG (G30) consumption
kg/h
4,54
Air flow (ΔT 15°C)
m³/h
5650
Air temperature rise (ΔT) at (min. - max.) heating power
°C
10,1 - 29,6
Fan data
Max. acoustic pressure level at a distance of 5 m from the unit
dB(A)
64
Installation data
Power supply
V/ph
230V 1N - 50 Hz
Power electric consumption
W
610
IP protection class
20
Gas connection
Ø "
M 3/4
Operating temperature range
°C
0 / +40
Installation type
B23, B23P, C13, C33, C53, C63
Recommended installation height
m
3,0 - 3,5
Exhaust air flue diameter
mm Ø
80
Air Inlet flue diameter
mm Ø
80
Dimensions
Width
mm
929
Depth
mm
743
Height
mm
777
Weight
kg
79

Dimensions

Model: NEXT-G 60
NEXT-G condensing and modulating gas fired unit heaters
Manuals 15.6 MB
Gas type change manual 2.7 MB
Room probe manual 1.3 MB
Catalogue 1.6 MB
MODBUS protocol for connection to BMS 155 KB
Re-Mote digital control panel
Manuals 3.5 MB
OSWR001 Genius software for NEXT-G gas fired heaters
Manuals 8 MB